Your whole radiology department in one system. On your premises.
Radiology information system · Image archive · Reporting
From registration to the appointment, the modality and the released report: one workplace in the browser, in Arabic, English and German. The server and the data stay with you, not in a cloud. Optionally with AI support that also runs on your premises.
- Scope
- RIS, PACS archive, web viewer, reporting, documents, patient access
- AI
- Add-on on your premises, also on the same server
- Operation
- Your own on-site server, works without internet
- Languages
- Arabic first (RTL), plus English and German
- Modalities
- DICOM receive and modality worklist
- Access
- 11 roles, second factor, LDAP/AD optional
- Status
- Version 0.1.0 · pilot phase
Approval by country
- Approval follows the country and its regulator. Before clinical use, the system obtains the approval that the country and its regulations require.
What the system does
Every module can be switched on separately. You start with what you need.
- Patient record
- Demographics with a complete correction history, search by name and number. Duplicate records are merged under a two-person rule and can be separated again.
- Orders and worklist
- Create and follow examinations: requested, scheduled, arrived, in progress, completed. Each role sees only the steps it may perform.
- Scheduling
- Rooms and devices with protection against double booking, check-in on the day, cancellation and no-show.
- Worklist at the modality
- Scheduled examinations appear on the device through DICOM modality worklist. Staff pick the patient instead of typing; mix-ups from typing errors disappear.
- Image archive (PACS)
- DICOM receive with automatic matching of unambiguous studies to their order. Anything doubtful goes to a review list and is assigned or rejected by a person.
- Image viewing
- Own web viewer straight from the examination: three planes (MPR) and 3D, windows by key (F2 lung, F3 bone, F4 soft tissue, F8 brain, F9 abdomen), measuring distance, angle, Cobb angle, area and density, comparison with the earlier examination. Each physician's layout per examination type is remembered (hanging protocol). Diagnostic use follows the qualification in the country concerned.
- Reporting
- Draft with templates, submit, release by a second reader (can be switched off), return with a reason, addenda. A released report cannot be changed.
- Seal and PDF/A
- Every released report receives a cryptographic system seal and can be exported as PDF/A-2b for long-term filing.
- Windows workstation
- A dedicated program for the reading desk: worklist and images side by side or the images on the second screen, comparison with the earlier examination in one step, a test pattern for the screen.
- Documents
- Upload referrals, consent forms and previous reports as PDF or image. Every file is scanned for malware before it is stored.
- Administration
- Overview of system state, waiting work and enabled functions. Users, roles and second factor in a dedicated administration console.
- AI in the viewer (add-on)
- A model finds the organs, bones and vertebrae of a CT, labels the vertebrae (C/T/L/S) in every plane and jumps to an organ with one click. It runs on the graphics card of the physician's computer when that card is strong enough – which relieves the server – and otherwise on the server. With several graphics cards the viewer picks the strongest; the physician can change it.
- AI pre-read (add-on)
- An image and language model looks at new examinations as soon as they arrive. When the study is opened, the suggestion sits next to the images; the physician confirms or rejects it. A suggestion, not a report.
- AI for reporting (add-on)
- Voice dictation; one click sorts the text into clinical question, technique, findings and impression without adding anything. Plus translation between Arabic, English and German and a spelling check. Nothing is taken over without a person.
- Critical findings
- The radiologist flags a critical finding; the referring physicians immediately see a red alarm until someone acknowledges it. Optionally also e-mail, SMS or WhatsApp, without the patient's name.
- Key images in the report
- Images the report text refers to appear in the report PDF right below the text.
- Patient access
- Link or QR code without an account: questionnaire before the examination (pacemaker, metal, allergy, pregnancy, kidneys, metformin, claustrophobia) with a warning to the team, images in a patient view, the released report explained in plain words (Arabic, English, German) and a guest link for a second opinion, valid for at most 7 days.
- Day board
- For reception and technologists: expected, in the waiting room with waiting time, in the device with running and remaining time, finished. Plus every device as free or busy with its next appointment.
- Follow-up in the viewer
- Comparison with the earlier examination as a difference map (risen red, fallen green) or a blend; the earlier series is fitted in space by itself – level, position and elastic bend in three directions. For confirmed lesions the viewer works out the sum of the longest diameters and the change by RECIST 1.1. Computed aids; the assessment stays with the physician.
- Notes, voice and measurements
- Report notes right beside the images, with dictation and measurements as references; voice commands in Arabic, English and German. Measurements can be stored in the archive as a DICOM presentation state (GSPS) so that other viewers show them, and held against the facility's list of reference values. An explanatory clip with voice is saved as MP4.
- PET-CT and modern image formats
- A second series lies exactly over the first, for example PET over CT. Brightness and contrast are worked out by the graphics chip of the workstation; the archive also reads HTJ2K-compressed images.
- Import report templates
- The facility keeps its templates in one file. Templates in the MRRT format, as RadReport offers them, are imported with one command; source and licence note stay with the text.
- Installed as a package, also without internet
- The server is set up from an RPM package. For sites without internet, one command collects everything needed on a medium; the installation then runs with no network access at all.
- All on one server
- On request the system and the AI models run together on a single server, without a second AI machine. The models are loaded in advance or installed from a USB stick – without internet.
- AI text assistant (add-on)
- Translates texts between Arabic, English and German, checks spelling and suggests an order for the waiting work – connected to an AI server in your own building, such as KM Code Craft AI. It only suggests.
What the work looks like
Screenshots of the real interface. Persons and details are invented; the images in the viewer come from public, anonymised research collections (The Cancer Imaging Archive: RIDER Lung CT, Lung-PET-CT-Dx, Pancreas-CT; CC BY).
- /products/radiologie/en-worklist.png
- Worklist: examinations with status and the next permitted steps
- /products/radiologie/en-board.png
- Day board: expected, waiting, in the device, finished – with a warning from the patient questionnaire
- /products/radiologie/en-viewer.png
- Viewer: three planes (MPR), vertebrae labelled in the image, next to them the organs found by the AI
- /products/radiologie/en-followup.png
- Follow-up: on the left the current CT with a difference map – risen red, fallen green –, on the right the earlier examination. The earlier series is fitted in space by itself
- /products/radiologie/en-fusion.png
- PET over CT: the metabolic image lies exactly over the CT, the lesion lights up in its place
- /products/radiologie/en-volume.png
- 3D view from the CT: bones and vessels as a body you can turn, worked out in the browser on the graphics chip
- /products/radiologie/en-report.png
- Reporting: draft, template, dictation, submit for release
- /products/radiologie/en-access.png
- Patient access: link and QR code, sent by SMS, WhatsApp or e-mail
- /products/radiologie/en-portal.png
- Patient page on the phone: the report explained in plain words
- /products/radiologie/en-schedule.png
- Schedule: room, start, duration – double booking is prevented by the server
- /products/radiologie/en-admin.png
- Administration: state, waiting work, enabled functions
Security and traceability
Patient data does not leave your building. Who did what can be proven.
- Fully on-premises; the system needs no internet connection in daily use.
- Sign-in with a second factor for authors, releasers and administrators; read-only connection to LDAP or Active Directory.
- Access separated by site and department at database level.
- Tamper-evident audit trail: every change and every record access is kept in a chained series of checksums that can be recomputed at any time.
- Released reports and document versions are immutable; corrections are made as an addendum or a new version.
- Backup with recovery to any point in time; the procedure is tested automatically.
- Encrypted connections, security headers and request-rate limiting by the reverse proxy in front.
- Uploads are scanned for malware before storage; without a reachable scanner nothing is accepted.
Technology
Proven open building blocks, cleanly connected. No third-party licence fees for the core components.
- Workplace
- Web application for current versions of Chrome and Edge; nothing to install on the workstation
- Server
- Linux with Docker; all services as hardened containers without root privileges
- Database
- PostgreSQL 17 with row-level access separation and continuous backup
- Image archive
- Orthanc (DICOM C-STORE, DICOMweb, modality worklist)
- Viewer
- Own web viewer (WebAssembly, WebGPU) through short-lived access links; also inside the Windows program
- AI (add-on)
- Models on your premises, without internet: organ finding (TotalSegmentator, Apache-2.0), image and text model (MedGemma), dictation (whisper), text assistant. On a separate AI server or on the same server as the system
- Sign-in
- Keycloak (OpenID Connect, TOTP), optional LDAP / Active Directory
- Interfaces
- DICOM, DICOMweb, REST API with OpenAPI 3.1 description, Prometheus metrics
- Not included
- HL7/FHIR interfaces, billing, teleradiology, personal qualified signature
- Server guideline
- For a small department: 8 cores, 32 GB RAM, SSD for the database, mirrored image storage sized by study volume, UPS, separate backup medium. With the language model on the same server: 16 cores and 64 GB RAM. Exact sizing follows from the site survey.
Tested, not just claimed
All checks run automatically and are recorded in the project log. The figures come from the development machine and are no promise for your hardware.
- Acceptance on the test site
- A whole working day with test accounts over the internet: registration to release, critical alarm with acknowledgement, questionnaire on the phone with a warning to the team, report explanation, organ finding in the viewer (17 Nov 2026)
- Automated tests
- More than 400 automated tests and 60 tests against a real database on every change
- Whole workflow in the browser
- Sign-in → appointment → examination → report → release by the second reader, with second factor, against a real server
- Modality connection
- Receive and worklist against a real DICOM archive with a simulated device, including Arabic names
- 30-minute endurance load
- 276,205 requests without an error, response time steady at 11 ms (95th percentile), memory stable
- Recovery
- 11 GB database restored to a chosen point in time in 75 seconds after a simulated total loss
- Report PDF
- PDF/A-2b with embedded fonts, Arabic and German
From first talk to daily operation
We deliver the system as a finished installation: hardware, installation, training and support.
- Demonstration and scope: which modules, how many workplaces, which modalities.
- Site survey: device list, network, storage need, retention periods, users and roles.
- Quotation covering hardware, installation and support.
- Set-up and installation with a documented acceptance test, connection of every device.
- Training per role with illustrated guides in Arabic and German.
- Trial operation with your department, your approval, then support and updates.
Included
- Software with all modules listed above
- Installation and operating manual, downtime procedure
- Training guides per role (Arabic, German) and training plan
- Interface description (OpenAPI)
- Templates for site survey, acceptance and handover
Done at your site
- Connection and testing with your modalities
- Acceptance test on your hardware, including measured recovery time
- Independent security test if you require one
- Clarifying the legal requirements of your country
- The content of your report templates
Frequent questions
- Does the AI need internet or a second server?
- No. The models run on your premises – on a separate AI server or together with the system on one server. Where possible, organ finding even runs on the graphics card of the physician's computer.
- Does the AI make diagnoses?
- No. It makes suggestions that are marked as such; the physician checks, confirms or rejects them. Only what a person releases is released.
- Do we need internet?
- No. The system runs entirely in your own network. Internet is only needed for remote support, if you want it.
- May the viewer be used for diagnosis?
- That follows the qualification and approval in the country concerned. Where an approved diagnostic workstation is required, the archive provides it with the images through DICOM.
- Which modalities can be connected?
- Devices that send DICOM. For the worklist at the device, the device must support modality worklist and be licensed for it. We clarify that in the site survey.
- Is the system approved as a medical device?
- No. Whether and which approval is required depends on your country and the intended use. We clarify this together before an installation.
- What does it cost?
- The price depends on hardware, number of devices and level of support. You receive a fixed quotation after the site survey.
- Who owns the data?
- You do. It lives on your server in open formats (DICOM, PostgreSQL, PDF/A).
See it for yourself.
We show you the system with sample data and discuss what your department needs.